Huawei R4850G2 CAN BUS Power Supply Settings
>> YOUR LINK HERE: ___ http://youtube.com/watch?v=_IKTpq7bXoI
CAN BUS R4850G2 Power Supply. How to set default and temporary output voltages. • Important: Note that this is a temporary mains connection for this video using only L and N. When connecting for use, be sure to also connect the GND connector to the mains GND (or Earth). • Examples: • On the fly: • (first 2 bytes 01 00) indicate changing value on the fly • frame;108180FE;01 00 00 00 00 00 D5 2A;100; • The 01 00 indicates send value. The D5 2A =54570 in decimal.And 54570/1020=53.5 volts • frame;108180FE;01 00 00 00 00 00 E9 16;100; • The 01 00 indicates send value. The E9 16 =59670 in decimal.And 59670/1020=58.5 volts • Change boot values: • (first 2 bytes 01 01) indicate changing default boot values: • frame;108180FE;01 01 00 00 00 00 D5 2A;100; • The 01 01 indicates boot value. The D5 2A =54570 in decimal.And 54570/1020=53.5 volts • CAN to USB: • https://www.amazon.com/Analyzer-CAN-B...
#############################