>> YOUR LINK HERE: ___ http://youtube.com/watch?v=bEqiyWg_Ats

The electrohydraulic system in this Mercedes-Benz SL is defective. • The roof has to be closed manually. • First, switch off the ignition. • On vehicles with Keyless-Go, remove the transmitter key from the vehicle. • Place the key outside the vehicle's reception range. • Open the trunk lid. • You will need these supports to carry out the next steps. • They are for your safety. • For the following work, you will need a colleague to help you. • Place the Vario roof in the load assist position. • Prop up the roof using the supports. • Fix the supports in place with adhesive tape or cable ties. • This will prevent the supports from slipping. • Take the Allen wrench from the vehicle tool kit. • Open the screw on the hydraulic pump. • Turn the screw no more than two rotations counterclockwise. • Using an assembly wedge, remove the screw covers on the side panel covers ... • ... in the trunk. • With the Allen wrench, release the locking mechanism of the tubular frame. • Do this on both sides. • Pull the tubular frame together with the trunk lid back and up in a steady motion. • The tubular frame could otherwise suffer damage. • Open the driver and passenger doors and lower the side windows. • This is necessary to avoid injury during the steps that follow. • The Vario roof can now be moved forward. • Fold the C-pillar upwards until it forms a 90 degree angle. • Be careful that the rear window does not collide with the rear shelf. • The roof mechanism could otherwise suffer damage. • Open the cover in the headliner. • Using the Allen wrench, open the latching mechanism completely. • Turn the wrench clockwise. • Move the Vario roof all the way to the front. • Insert the latch hooks into the left and right latch sockets. • You won't need the supports any more so you can remove them. • Fold down the trunk lid and secure it in the trunk lid lock. • Use Star Diagnosis to fold in the side flaps on the trunk lid. • Open the menu and select Main groups . • Select Control units and then Body . • Select UVS Rollover bar and then Actuation . • Select Actuations for emergency operation . • Select Folding side flaps in/out. • Press F3 to fold in the side flaps. • If the side flaps cannot be actuated using Star Diagnosis, ... • ... you will have to fold them in using an emergency actuation method. • Open the trunk. • Press the tubular frame towards the front until the latch hooks on the hinge lever are in the lock position. • Turn the screws until the latches of the tubular frame are locked. • Do this on both sides. • Replace the covers on both sides. • Relock the hydraulic pump and then the roof. • Do the same as you did when unlocking the roof. • Except now turn the Allen wrench counterclockwise. • The roof is now properly closed and latched. • More Information: • AR 77.30-P-63 69 R • 230 589 06 63 00 • -------------------------------------------------------------------------------------- • instagram: •   / mbownersclub   • twitter: •   / mb_owners  

#############################









Content Report
Youtor.org / YTube video Downloader © 2025

created by www.youtor.org