My Amana furnace is not working I did There is 3 blink











>> YOUR LINK HERE: ___ http://youtube.com/watch?v=ulCnemMeyFM

From https://www.justanswer.com/ythi • JustAnswer Customer: Hi • Pearl Wilson: Assistant: Hi. • Pearl Wilson: Assistant: How can I help? • JustAnswer Customer: My Amana furnace is not working • Pearl Wilson: Assistant: Did you check the furnace's filters? • JustAnswer Customer: Yes I did, There is 3 blink error • Pearl Wilson: Assistant: Do you plan on doing the work yourself? • JustAnswer Customer: Yes I do • Pearl Wilson: Assistant: Anything else we should know to help you best? • JustAnswer Customer: Fan is working, red led is blinking 3 times • HVAC Guru: HVAC TECH: One moment please. • HVAC Guru: HVAC TECH: Note it takes time to type and add links so please be patient. • HVAC Guru: HVAC TECH: Also the site will send you a phone call offer, that is not me. • HVAC Guru: HVAC TECH: That is a pressure switch code, meaning the pressure switch is not closing when the exhaust fan is coming on. • HVAC Guru: HVAC TECH: So you need to check and make sure the exhaust fan comes on first. • HVAC Guru: HVAC TECH: You can cycle the power off to the unit at the switch or breaker for a minute and turn it back on to clear the code and restart a heat cycle making sure the thermostat is on or you have R to W jumpered on the board in the furnace. • HVAC Guru: HVAC TECH: If the fan does not come on check the fan for power. • HVAC Guru: HVAC TECH: If the fan does come on and nothing is plugged in the exhaust or intake vent then check the pressure tube for blockages. • HVAC Guru: HVAC TECH: That is the rubber tube that connects the pressure switch to the blower housing. • HVAC Guru: HVAC TECH: If that tube is blocked or cracked that code will come up. • HVAC Guru: HVAC TECH: You need to check the port where the tube connects to the exhaust blower housing make sure that port is not blocked with crud. • HVAC Guru: HVAC TECH: Normally it is one of these issues causing that code on the furnace. • HVAC Guru: HVAC TECH: Lastly you have to check all condensate lines on the unit, especially the drain line that comes out of the inducer motor housing to make sure nothing is blocked causing a backup of condensate water. • HVAC Guru: HVAC TECH: All I ask is. • HVAC Guru: HVAC TECH: Please remember to use the RATING LINK ON YOUR PAGE by selecting a star at the top or bottom of the screen before you leave today. • HVAC Guru: HVAC TECH: Even though you paid the site they will not disburse any part of it to me until you supply a good rating. • HVAC Guru: HVAC TECH: If you need anything else, just let me know. • HVAC Guru: HVAC TECH: You can continue asking follow-up questions at no additional charge after rating my service if you still need assistance. • Pearl Wilson: Assistant: If you have a home improvement or appliance question and want to chat with an expert now visit justanswer.com/ythi

#############################









Content Report
Youtor.org / YTube video Downloader © 2025

created by www.youtor.org