How to calibrate the Elcometer 456 Scan Probe
>> YOUR LINK HERE: ___ http://youtube.com/watch?v=80zO-ZLAEIM
It is critical to calibrate a coating thickness gauge to ensure the highest level of measurement accuracy. Digital coating thickness gauges can be calibrated using certified standards or precision foils, also referred to as calibration shims. • Calibration is the process of setting the gauge to known values of thickness to ensure accuracy on different substrate types, shapes and surface finishes. • Calibrating the Elcometer 456 Coating Thickness Gauge with Ultra/Scan Probe is really easy. Simply select the Auto Repeat Mode and follow the on-screen prompts to ensure the highest level of measurement accuracy. The Elcometer 456’s patented offset feature ensures any cap wear during use is incorporated within the calibration procedure. • For more information on the Elcometer 456 Coating Thickness Gauge and Ultra/Scan Probe, please contact Elcometer at [email protected] or visit our website: http://elcometer.com/en/coating-inspe... • ----- • Click here to download the video script in English: https://www.elcometer.com/pub/media/P... • ----- • STANDARDS: • AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 1186-B, ASTM D 1400, ASTM D 7091, ASTM E 376, ASTM G 12, BS 3900-C5-6B, BS 3900-C5-6A, BS 5411-11, BS 5411-3, BS 5599, DIN 50981, DIN 50984, ECCA T1, EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83), ISO 1461, ISO 19840, ISO 2063, ISO 2360, ISO 2808-6A, ISO 2808-6B, ISO 2808-7C, ISO 2808-7D, ISO 2808-12, NF T30-124, SS 184159, SSPC PA 2, US Navy PPI 63101-000, US Navy NSI 009-32
#############################