ETROA01 DC 12V24V 1DI1DO2DI2DO Ethernet Modbus RTU TCP Relay Board











>> YOUR LINK HERE: ___ http://youtube.com/watch?v=kMNOgXgO6sY

ETROA01 DC 12V/24V Multifunction Network Relay Ethernet To RS485 Serial Serve LAN RJ45 Modbus MQTT TCP UDP PLC IO Expanding Board • Product link: https://eletechsups.com/index.php?mai... • WhatsApp+8613926226566 • Features: • 1DI-1DO Version: • 1 Working voltage: DC 12V (12V version); 24V (24V version) • 2 Working current (12V): Standby 19MA, single relay ON current 35MA, maximum working current 53MA (1 relay ON) • 3 1x photoelectrically isolated input ports (NPN low-level active), the input-output relationship can be set to Unrelated (default)/Self- locking/Momentary/Output=Input. • 4 1x relay output ports,1x NPN switch input ports, • 5 Communication interface: RS485/Ethernet (optional) • 6 Standard MOSBUS instructions: Write 05/06/15/16, Read 01/02/03 • 7 Set the Slave Address through the DIP switch (A0-A5), which can support up to 63 devices in parallel. • 8 Through the DIP switch (SW1=ON), the Ethernet and RS485 ports can be set as Ethernet to RS485 servers. • 9 The default baud rate is 9600BPS, the baud rate can be selected through jumpers 2400 4800 19200 38400 57600 115200BPS • 10 You can choose the check mode as No Parity, Even Parity and Odd Parity. • 11 You can set the data sending return time, the maximum can be set to 1000ms • 12 Size :55*72*22mm (only board),58*88*45mm (with din rail box): • 13 Weight: 45g (only board);96g (with din rail box) • 14 Maximum load: 10A/250VAC, 10A/125VAC, 10A /30VDC, 10A /28VDC, 10A /12VDC • • 2DI-2DO Version: • 1 Working voltage: DC 12V (12V version); 24V (24V version) • 2 Working current (12V): Standby 19MA, single relay ON current 35MA, maximum working current 90MA (2 relay ON) • 3 2x photoelectrically isolated input ports (NPN low-level active), the input-output relationship can be set to Unrelated (default)/Self- locking/Interlocking/Momentary/Interlocking(2 ch)/Output=Input. • 4 2x relay output ports,2x NPN switch input ports, • 5 Communication interface: RS485/Ethernet (optional) • 6 Standard MOSBUS instructions: Write 05/06/15/16, Read 01/02/03 • 7 Set the Slave Address through the DIP switch (A0-A5), which can support up to 63 devices in parallel. • 8 Through the DIP switch (SW1=ON), the Ethernet and RS485 ports can be set as Ethernet to RS485 servers. • 9 The default baud rate is 9600BPS, the baud rate can be selected through jumpers 2400 4800 19200 38400 57600 115200BPS • 10 You can choose the check mode as No Parity, Even Parity and Odd Parity. • 11 You can set the data sending return time, the maximum can be set to 1000ms • 12 Size :67*72*22mm (only board),70*88*45mm (with din rail box): • 13 Weight: 62g (only board);118g (with din rail box) • 14 Maximum load: 10A/250VAC, 10A/125VAC, 10A /30VDC, 10A /28VDC, 10A /12VDC • • Please contact me for detailed information!

#############################









Content Report
Youtor.org / Youtor.org Torrents YT video Downloader © 2024

created by www.mixer.tube